10KV H-class dry-type power transformer10KV H-class dry-type power transformer10KV H-class dry-type power transformer10KV H-class dry-type power transformer10KV H-class dry-type power transformer10KV H-class dry-type power transformer10KV H-class dry-type power transformer
  • 10KV H-class dry-type power transformer
  • 10KV H-class dry-type power transformer
  • 10KV H-class dry-type power transformer
  • 10KV H-class dry-type power transformer
  • 10KV H-class dry-type power transformer
  • 10KV H-class dry-type power transformer
  • 10KV H-class dry-type power transformer
  • 1/7
  • 10KV H-class dry-type power transformer
  • 10KV H-class dry-type power transformer
  • 10KV H-class dry-type power transformer
  • 10KV H-class dry-type power transformer
  • 10KV H-class dry-type power transformer
  • 10KV H-class dry-type power transformer
  • 10KV H-class dry-type power transformer

10KV H-class dry-type power transformer

Cooling method 三相式
WhatsApp
RESERVATION
Detail

Product Details of SG(B)10 H-Class Dry-Type Power Transformer


I. Product Overview

The SG(B)10 H-Class dry-type power transformer is a crucial device in the power system. It is manufactured with advanced technology and high-quality materials, featuring high efficiency, reliability, and safety. It is widely used in various places with high requirements for power supply quality and safety, such as commercial centers, hospitals, schools, and factories.


II. Product Features

(1) High Insulation Grade

This transformer uses H-class insulation materials, which have excellent heat resistance. H-class insulation can withstand high temperatures, ensuring stable insulation performance even in long-term operation under high ambient temperatures or heavy loads, significantly extending the transformer's service life.


(2) Environmentally Friendly and Energy Efficient

The SG(B)10 H-Class dry-type power transformer takes environmental protection and energy conservation into full consideration during design and manufacturing. It has relatively low no-load and load losses, effectively reducing energy consumption and operating costs. Moreover, it does not use transformer oil, avoiding oil leakage and environmental pollution, meeting the modern society's requirements for environmentally friendly products.


(3) Safe and Reliable

1. Reasonable Structure Design: The transformer has a sturdy casing and a well-designed internal structure, effectively resisting external mechanical shocks and vibrations.

2. Complete Protection Functions: It is equipped with multiple protection devices such as overcurrent, overvoltage, and short circuit protection. When abnormal conditions occur, it can promptly cut off the circuit to protect the equipment and personnel's safety.

3. Good Fire Resistance: Due to its dry design, it does not use flammable transformer oil, thus having excellent fire resistance and reducing the risk of fire to a certain extent.


(4) Convenient Operation and Maintenance

1. No Special Maintenance Required: Unlike oil-immersed transformers, dry-type transformers do not need complex maintenance work such as regular oil level checks and oil replacement.

2. Good Heat Dissipation: The transformer uses natural air cooling or forced air cooling for heat dissipation, with high efficiency, ensuring it operates within the normal temperature range.


III. Technical Parameters

(1) Rated Capacity: The common rated capacity range is from several hundred kVA to several thousand kVA, and users can choose according to their actual needs.

(2) Rated Voltage: It includes the primary side rated voltage and the secondary side rated voltage. The primary side rated voltage is generally 10kV, 20kV, etc., and the secondary side rated voltage is usually 0.4kV.

(3) No-load Loss and Load Loss: No-load loss refers to the power loss of the transformer when it is running no-load, and load loss refers to the power loss when it is running at rated load. The specific loss values depend on the transformer's rated capacity and design requirements.

(4) Impedance Voltage: Impedance voltage is an important parameter of the transformer, reflecting the influence of the internal winding resistance and reactance on the voltage. Generally, the impedance voltage range is between 4% and 6%.


IV. Application Scenarios

(1) Commercial Places: Such as large shopping malls, shopping centers, office buildings, etc. These places have high requirements for power supply reliability and stability, and the SG(B)10 H-Class dry-type power transformer can meet their needs, providing stable power supply for various commercial equipment.

(2) Medical Institutions: Hospitals have extremely high requirements for power quality. Any power outage or voltage fluctuation may affect the normal operation of medical equipment and endanger patients' lives. The high reliability and stability of this transformer can provide reliable power support for various medical equipment in hospitals.

(3) Industrial Sites: Various production equipment in factories have high power demands and also require high voltage stability. SG(B)10 H-class dry-type power transformer can adapt to the harsh environment of industrial production and provide stable and reliable power support for industrial production.

(4) Public places such as schools, libraries, and stadiums, where there are dense crowds, have high requirements for the safety and reliability of power supply. The safety and environmental performance of this transformer can meet the usage requirements of public places.

V. Installation and Commissioning

(1) Installation

1. Installation location selection: The transformer should be installed in a dry, well-ventilated place free of corrosive gases and dust. At the same time, there should be sufficient space at the installation location for the maintenance and repair of the transformer.

2. Foundation construction: A suitable foundation should be made according to the size and weight of the transformer. The foundation should be firm and flat, capable of bearing the weight of the transformer and the vibration during operation.

3. Transformer positioning: Use a crane or other lifting equipment to lift the transformer onto the foundation and fix it in place.

(2) Commissioning

1. Visual inspection: Before commissioning, visually inspect the transformer to ensure it is undamaged and undistorted, and that all connection points are secure and reliable.

2. Electrical performance testing: Test the insulation resistance, DC resistance, and transformation ratio of the transformer to ensure that all indicators meet the standard requirements.

3. No-load trial operation: After completing the electrical performance testing, conduct a no-load trial operation. The no-load trial operation time is generally 24 hours. During the trial operation, closely observe the operation of the transformer, such as temperature and sound, to ensure normal operation.

VI. Maintenance and Care

(1) Regular inspection

1. Visual inspection: Regularly inspect the appearance of the transformer to check for cracks, deformations, moisture, etc.

2. Electrical connection inspection: Check if the electrical connection points of the transformer are loose or overheating. If any abnormalities are found, they should be dealt with promptly.

3. Temperature inspection: Regularly check the temperature of the transformer to ensure it operates within the normal temperature range.

(2) Cleaning and maintenance: Regularly clean the transformer's casing and heat sinks to remove dust and debris, ensuring good heat dissipation performance.

(3) Preventive testing: Regularly conduct preventive tests on the transformer, such as insulation resistance testing and withstand voltage testing, to promptly identify potential safety hazards.

VII. After-sales Service

After purchasing the SG(B)10 H-class dry-type power transformer, the manufacturer usually provides comprehensive after-sales service, including technical support, fault repair, and spare parts supply. During the product's warranty period, if any quality issues arise, the manufacturer will provide free repair or replacement. Additionally, the manufacturer will regularly visit users to understand the usage of the product and provide better service.